Evenson Power Aerial Bundle Cable (ABC) brings the safety and reliability of insulated conductors to overhead distribution.
Aerial Bundle Cable, widely known as ABC, modernizes overhead distribution by replacing separated bare conductors with insulated cores twisted into a compact bundle. Evenson Power manufactures low and medium voltage ABC engineered for the reliability, safety, and economy that today’s distribution networks require.
Because the conductors are insulated and bundled, ABC dramatically reduces the risk of short circuits from tree contact, wind-driven clashing, and animal bridging. The result is a network that is safer to the public, cheaper to maintain, and more resistant to power theft.
ABC is an overhead cable in which two, three, or four insulated phase conductors are stranded helically around a central or peripheral neutral conductor that doubles as the mechanical messenger. The neutral may be a bare or insulated all-aluminum-alloy conductor sized to support the mechanical load of the bundle, so the cable supports its own weight across the span without a separate catenary wire.
Evenson Power ABC is supplied in self-supporting configurations for both street lighting and distribution, with conductor sizes and core counts to suit service drops, mains, and three-phase feeders. Because the conductors are individually insulated and held tightly together, the phases cannot clash in the wind and accidental contact does not cause a fault, fundamentally changing the safety and reliability profile compared with traditional open-wire overhead lines.
Evenson Power ABC conductors are stranded from electrical-grade aluminum, with the load-bearing neutral messenger produced from high-strength 6201 aluminum alloy where it carries the mechanical tension of the span. Phase conductors are insulated with weather-resistant, cross-linked polyethylene (XLPE/XLPE-UV) formulated to resist ultraviolet light, heat, and abrasion over decades of outdoor exposure.
The insulated cores are laid up helically around the neutral to form a compact, stable bundle that distributes mechanical load and keeps the conductors together under wind and ice. Black, carbon-loaded insulation provides excellent UV stability for long outdoor life.
Evenson Power ABC is produced for low voltage service at 0.6/1 kV and for medium voltage covered overhead applications up to about 33 kV. Phase conductor sizes range from compact service-drop sections to substantial feeder sizes.
Configurations cover duplex and triplex service drops, quadruplex mains with neutral, and multi-core assemblies that include street-lighting conductors, letting one product family serve the whole low-voltage overhead network.
The insulated, bundled design of ABC delivers tangible operational advantages over traditional bare overhead lines. Faults from conductor clashing and vegetation contact are largely eliminated, public safety is improved, and illegal connections become far more difficult. Installation is faster because narrower right-of-way and simpler hardware are required, and ongoing maintenance costs fall sharply because the line is far less sensitive to trees and weather.
For utilities, the cumulative effect is a measurable reduction in outage frequency and duration, fewer storm-related repairs, and lower vegetation-management spending over the life of the network. For the public, insulated conductors mean a dramatically safer overhead system in built-up areas. These benefits make ABC the preferred choice for new low-voltage distribution and for upgrading aging bare-wire networks.
Evenson Power ABC is ideal for overhead distribution in urban, suburban, rural, and coastal areas where reliability and safety are priorities. It is widely used for service drops to homes and businesses, low-voltage street mains, and combined power-and-lighting circuits, as well as covered medium-voltage lines through wooded corridors.
Evenson Power ABC is manufactured and tested to recognized international standards for self-supporting bundled overhead cable, covering conductor properties, insulation thickness, weather and UV resistance, and mechanical strength of the messenger.
Verification includes insulation resistance, high-voltage withstand, tensile testing of the bearer, and accelerated weathering to confirm long outdoor life.
ABC is installed using suspension and dead-end assemblies clamped to the neutral messenger, which carries the mechanical load. Evenson Power ABC is supplied on reels ready for stringing, and its self-supporting design allows rapid installation with fewer poles and simpler hardware than bare lines.
Insulation-piercing connectors allow tap-offs without cutting the main run, and correct tensioning of the messenger ensures proper sag. The insulated cores tolerate contact with structures and vegetation far better than bare conductors.
Evenson Power ABC combines high-quality aluminum conductors, robust alloy messengers, and durable UV-stable insulation to deliver overhead distribution cable built for safety and longevity. Every reel is produced under controlled processes and verified against the standards that utilities rely on.
Choosing Evenson Power ABC means fewer outages, safer networks, lower maintenance, and a partner committed to delivering consistent quality for distribution projects of every scale.
Evenson Power aerial bundled cable is manufactured under continuous process control, with XLPE insulation extruded and cured to ensure uniform wall thickness, full cross-linking, and consistent dielectric strength along the entire length. Conductor stranding, diameter, and resistance are monitored in line, and the insulation is checked for concentricity and integrity using high-voltage spark testing during production.
Finished cable is sample-tested for conductor resistance, insulation thickness, tensile strength and elongation, hot-set behaviour of the cross-linked insulation, and high-voltage withstand. The carbon-black formulation of the insulation is verified for ultraviolet resistance, ensuring the cable retains its mechanical and electrical properties through prolonged outdoor exposure to sunlight and weather.
Each drum is supplied with a routine test report and is clearly marked with cable type, size, length, and production batch for full traceability from factory to field.
Evenson Power ABC is engineered for fast, safe overhead installation along poles and building facades. The self-supporting messenger or insulated bundle carries the mechanical tension, reducing the number of insulators and hardware compared with bare-conductor lines, and the twisted assembly keeps phases insulated and spaced to virtually eliminate phase-to-phase faults from wind, vegetation, and animal contact.
Because the conductors are individually insulated, the system tolerates tree contact and accidental touch far better than open wires, dramatically reducing outages, illegal tapping, and the maintenance burden of right-of-way clearing. Standard suspension, tension, and anchoring clamps make the bundle quick to dead-end and tension, and connections are made with insulation-piercing connectors that require no stripping of the main line.
The UV-stabilized XLPE and weather-resistant construction give the cable a long outdoor service life with minimal degradation, lowering the total cost of ownership of the distribution network.
| Cable type | Self-supporting Aerial Bundle Cable (ABC) |
| Phase conductor | Stranded aluminum, 1350-H19 |
| Neutral / messenger | 6201 aluminum alloy (AAAC), bare or insulated |
| Insulation | Black UV-stabilized XLPE |
| Voltage grade | 0.6/1 kV (LV); up to 33 kV (covered MV-ABC) |
| Phase conductor sizes | 16–150 mm² (and larger) |
| Configurations | Duplex, triplex, quadruplex, multi-core |
| Number of cores | 2, 3, 4 + neutral / lighting cores |
| Lay-up | Helically stranded bundle |
| Conductor temperature | 90°C continuous (XLPE) |
| UV / weather resistance | High (carbon-loaded XLPE) |
| Messenger function | Carries mechanical span load |
| Connection method | Insulation-piercing connectors |
| Standards | IEC 60502-1, IEC 61089, BS 7870-5, ASTM |
| Tests | Insulation resistance, HV withstand, tensile, weathering |
| Application | Overhead LV/MV distribution and service drops |
Engineered, certified and delivered under the Evenson Power name.