Evenson Power supplies the complete range of power transformer accessories: bushings, on-load and off-circuit tap changers, Buchholz relays, radiators and coolers, conservators, temperature monitors, pressure-relief devices, oil-level gauges, breathers, and more.
A power transformer is only as reliable as its accessories. The components mounted on and around the active part handle voltage transition through the tank wall, regulate output voltage, manage cooling, accommodate oil expansion, and provide the protection and monitoring that prevent small faults from becoming catastrophic failures.
Evenson Power offers a comprehensive portfolio of transformer accessories, engineered to integrate seamlessly with oil-immersed and dry type transformers alike. Whether equipping a new build or refurbishing an existing fleet, customers can source matched, standards-compliant components from a single trusted brand.
Bushings carry energized conductors through the grounded tank wall while maintaining insulation and controlled electric-field grading. Evenson Power supplies porcelain and polymer (composite) bushings, including oil-impregnated paper (OIP) and resin-impregnated paper (RIP/RIS) condenser types for higher voltage classes, complete with grading rings and creepage-rated surfaces for polluted or coastal environments.
Each bushing is selected for the system voltage class, rated current, and basic insulation level, and is tested for partial discharge, capacitance and tan-delta, and dielectric withstand.
Tap changers adjust the transformer turns ratio to regulate output voltage. Evenson Power offers On-Load Tap Changers (OLTC) for regulation under load using diverter/selector switching, and De-energized (off-circuit) Tap Changers for adjustment when the transformer is isolated.
Units are rated for the system current and step voltage, with motor-drive mechanisms, control cabinets, and tap-position indication available for OLTC applications. Robust contacts and proven switching mechanisms ensure a long maintenance interval.
The Buchholz (gas-actuated) relay, mounted in the pipe between tank and conservator, detects gas accumulation from incipient faults and surges in oil flow from severe faults, providing alarm and trip signals. Evenson Power also supplies pressure-relief devices that rapidly vent dangerous internal overpressure to protect the tank, and sudden-pressure relays for fast fault detection.
These protection accessories are coordinated with the transformer’s ratings to give early warning of developing faults and to limit damage when faults occur.
Radiators, detachable cooler banks, and fan/pump assemblies dissipate the heat generated by losses, keeping winding and oil temperatures within design limits. Evenson Power offers pressed-steel panel radiators, tubular radiators, and forced-cooling (ONAF/OFAF) packages with cooling fans and oil pumps.
Cooling capacity is matched to the transformer rating and ambient conditions, with corrosion-protected finishes for long outdoor life.
The conservator tank accommodates the expansion and contraction of insulating oil with temperature. Evenson Power supplies conservators with rubber-bladder or diaphragm air-cell systems that isolate the oil from the atmosphere, plus silica-gel breathers that dry incoming air to keep moisture out of the oil.
Oil-level gauges (magnetic dial and prismatic types) give clear local indication and remote alarm contacts, completing the oil-preservation system.
Accurate temperature monitoring protects insulation life. Evenson Power supplies oil-temperature indicators (OTI) and winding-temperature indicators (WTI) with dial, capillary, and electronic types, providing local readout, multi-stage alarm/trip contacts, and cooling-control outputs.
Advanced electronic monitors and digital relays add remote communication, data logging, and integration with substation control and SCADA systems for condition-based maintenance.
All Evenson Power accessories are manufactured and tested to the international standards applicable to each component family, covering bushings, tap changers, gas-actuated relays, cooling equipment, and instrumentation. Components undergo dielectric, mechanical, thermal, and functional testing as appropriate to their type.
Supported compliance and certification marks across the accessory range include IEC, UL, CE, KEMA, and TUV, ensuring compatibility and interchangeability across transformer fleets.
Evenson Power accessories are supplied ready for straightforward mounting on standard transformer fittings, with documentation for correct installation, commissioning, and connection of alarm/control wiring. Correct gasket selection and torque, and verification of relay and gauge function, are part of recommended commissioning.
Routine maintenance includes checking breather silica-gel color, verifying oil levels and temperatures, functionally testing protection relays, inspecting bushings for cleanliness and integrity, and exercising tap changers per the maintenance schedule.
Sourcing accessories from Evenson Power means matched, compatible, standards-compliant components from one supplier, simplifying procurement and spares management. The breadth of the range, from bushings to digital monitors, covers every protection, monitoring, and cooling need.
Backed by rigorous quality control and responsive technical support, Evenson Power accessories help transformers run safely, efficiently, and reliably throughout their service life.
Every Evenson Power transformer accessory is manufactured and tested to the same exacting standard as the transformers they protect and serve. Bushings undergo power-frequency withstand, partial discharge, and capacitance and tan-delta measurement to confirm dielectric integrity, while tap changers are mechanically cycled through their full operating range and verified for contact resistance, sequence, and transition timing before dispatch.
Protective devices receive functional verification appropriate to their duty. Buchholz relays are tested for gas-collection and surge-trip operation, oil-level gauges are calibrated against reference marks, and pressure relief devices are checked for accurate set-point operation and reseal. Radiators and conservators are pressure- and leak-tested to confirm sealing integrity under operating and transient conditions.
Each accessory is supplied with a test or calibration certificate, and components can be matched and pre-fitted to Evenson Power transformers so that interfaces, gaskets, and mounting flanges align perfectly on arrival.
Evenson Power maintains a broad inventory of standard bushings, tap changers, Buchholz relays, conservators, radiators, and oil-level gauges, alongside the capability to manufacture to specific ratings, creepage distances, and mounting interfaces. When ordering, clients are encouraged to supply the transformer rating, voltage class, mounting orientation, and existing flange or gasket dimensions so that components can be matched precisely to the installation.
The technical team provides selection guidance, retrofit drawings, and compatibility checks for both new builds and refurbishment of legacy units. Where an exact replacement is unavailable, Evenson Power can reverse-engineer interfaces from sample parts or drawings to ensure a drop-in fit without modification to the transformer tank or cover.
Spare-part kits, gasket sets, and recommended stocking lists are available to support maintenance programmes, minimizing downtime when a component must be replaced in service.
| Bushings | Porcelain & polymer; OIP / RIP-RIS condenser types |
| Bushing Voltage Class | Up to 72.5 kV and above (per application) |
| Tap Changers | OLTC (on-load) and DETC (off-circuit) |
| OLTC Features | Motor drive, control cabinet, position indication |
| Buchholz Relay | Two-stage gas-actuated, alarm + trip |
| Pressure Relief | Spring-loaded PRD; sudden-pressure relay option |
| Radiators / Coolers | Pressed-steel panel & tubular; detachable banks |
| Forced Cooling | Cooling fans and oil pumps (ONAF/OFAF) |
| Conservator | Bladder / air-cell oil-preservation type |
| Breather | Silica-gel; standard & maintenance-free |
| Oil-Level Gauge | Magnetic dial & prismatic, with alarm contacts |
| Temperature Monitors | OTI & WTI; dial, capillary or electronic |
| Monitor Outputs | Multi-stage alarm/trip + cooling control |
| Digital Monitoring | SCADA / communication-enabled options |
| Materials | Steel, porcelain, polymer, copper, resin (per part) |
| Standards | IEC / UL / CE / KEMA / TUV |
Engineered, certified and delivered under the Evenson Power name.