SZ Series OLTC 1000kva Mini distribution 12kv Miniature Substation Transformer

1. The SZ Series OLTC 1000kva Miniature Substation Transformer can be tested only after all the test items are qualified.
2. The SZ Series OLTC 1000kva Miniature Substation Transformer should also be checked before the trial operation.
3. SZ Series OLTC 1000kva Miniature Substation Transformer does 5 shock tests (closing test).
4. The no-load running time is related to the capacity of the SZ Series OLTC 1000kva Miniature Substation Transformer, generally not less than 24 hours.
5. After the no-load running time is completed, the SZ Series OLTC 1000kva Miniature Substation Transformer will re-load.
6. Oil leakage of iron castings The main reason for oil leakage is that there are sand holes and cracks in the iron castings. For crack leakage, drilling crack prevention holes is the best way to avoid stress extension.
7. During treatment, lead wire can be driven into the leak point or riveted with a hand hammer according to the condition of the crack. Then clean the leaking point with the material and seal it with the material.

Fastest Delivery

3 Month DDP or the next business day shipping or local pickup.

14-Day Free Returns

Shop with confidence knowing you can return unopened products.

Multiple Payments

Pay securely with Crypto or Debit/Credit card.

1 Year Manufacture Warranty

On all our products, ensuring your investment is protected.

Share This Product

Description

1. The SZ Series OLTC 1000kva Miniature Substation Transformer can be tested only after all the test items are qualified.
2. The SZ Series OLTC 1000kva Miniature Substation Transformer should also be checked before the trial operation.
3. SZ Series OLTC 1000kva Miniature Substation Transformer does 5 shock tests (closing test).
4. The no-load running time is related to the capacity of the SZ Series OLTC 1000kva Miniature Substation Transformer, generally not less than 24 hours.
5. After the no-load running time is completed, the SZ Series OLTC 1000kva Miniature Substation Transformer will re-load.
6. Oil leakage of iron castings The main reason for oil leakage is that there are sand holes and cracks in the iron castings. For crack leakage, drilling crack prevention holes is the best way to avoid stress extension.
7. During treatment, lead wire can be driven into the leak point or riveted with a hand hammer according to the condition of the crack. Then clean the leaking point with the material and seal it with the material.

Reviews

There are no reviews yet.

Be the first to review “SZ Series OLTC 1000kva Mini distribution 12kv Miniature Substation Transformer”

Your email address will not be published. Required fields are marked *

Related Products

Customer Reviews

5/5

“A review from a customer who benefited from your product. Reviews can be a highly effective way of establishing credibility and increasing your company's reputation.”

5/5

“A review from a customer who benefited from your product. Reviews can be a highly effective way of establishing credibility and increasing your company's reputation.”